Gbs-elektronik MCA-527 Firmware Commands Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Équipement Gbs-elektronik MCA-527 Firmware Commands. GBS Elektronik MCA-527 Firmware Commands User Manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 54
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
MCA-527
Digital Multi-Channel Analyzer
GBS Elektronik GmbH
Bautzner Landstraße 22
01454 Großerkmannsdorf
Germany
Tel.: 0049 (0)351 21 70 07 - 0
Fax: 0049 (0)351 21 70 07 - 21
Website: www.gbs-elektronik.de
Description of the MCA527
Firmware Commands
Vue de la page 0
1 2 3 4 5 6 ... 53 54

Résumé du contenu

Page 1 - Firmware Commands

MCA-527Digital Multi-Channel AnalyzerGBS Elektronik GmbHBautzner Landstraße 2201454 GroßerkmannsdorfGermanyTel.: 0049 (0)351 21 70 07 - 0Fax: 0049

Page 2

MCA527Command name CMD_SET_INPUT_POLARITYCompatibility Identical to the MCA166 command.Execution right NecessaryDescription The command sets the input

Page 3

Description of the MCA527 Firmware CommandsCommand name CMD_SET_THRESHOLDCompatibility Identical to the MCA166 command.Execution right NecessaryDescri

Page 4

MCA527Command name CMD_SET_TRIGGER_FILTERCompatibility New MCA527 command.Execution right NecessaryDescription The command sets the trigger filters us

Page 5

Description of the MCA527 Firmware CommandsCommand name CMD_SET_FLAT_TOP_TIMECompatibility New MCA527 command.Execution right NecessaryDescription The

Page 6

MCA527Command name CMD_SET_PURCompatibility Identical to the MCA166 command.Execution right NecessaryDescription The command sets the pile up rejectio

Page 7

Description of the MCA527 Firmware CommandsCommand name CMD_SET_MEASURE_PZCCompatibility Compatible to the MCA166 command.Execution right NecessaryDes

Page 8

MCA527Command name CMD_SET_GATINGCompatibility New MCA527 command.Execution right NecessaryDescription The command sets the parameter (mode, signal an

Page 9

Description of the MCA527 Firmware CommandsMCA Stabilization Commands: Command nameCMD_SET_STABILISATIONCompatibility Compatible to the MCA166 command

Page 10

MCA527Command name CMD_SET_BIASCompatibility Compatible to the MCA166 command.Execution right NecessaryDescription The command sets the detector high

Page 11

Description of the MCA527 Firmware CommandsMCA Data Setup Commands:Command nameCMD_SET_TDFCompatibilityCompatible to the MCA166 command. The command

Page 12

MCA527Exclusion of liabilityThe information in this document has been carefully reviewed and is believed to beaccurate and reliab

Page 13

MCA527Command name CMD_SET_TIMECompatibility New MCA527 command.Execution right NecessaryDescription The command sets the time (t) on the internal clo

Page 14

Description of the MCA527 Firmware CommandsCommand name CMD_SET_TTL_LEVELSCompatibility New MCA527 command.Execution right NecessaryDescription The co

Page 15

MCA527Command name CMD_SET_AHRC_PARAMCompatibility New MCA527 command (since firmware version 14.00).Execution right NecessaryDescription The command

Page 16

Description of the MCA527 Firmware CommandsMCA Extension Port Commands:Command name CMD_SET_EXTENSION_PORTCompatibility New MCA527 command.Execution r

Page 17

MCA527Command name CMD_SET_EXTENSION_PORT (Continuation)Remarks The parts of the extension port are attached to the following pins.Full version OEM ve

Page 18

Description of the MCA527 Firmware CommandsCommand name CMD_SET_EXTENSION_PULSER_WIDTHCompatibility New MCA527 command.Execution right NecessaryDescri

Page 19

MCA527Command name CMD_WRITE_EXTENSION_RS232_TX_ASCIICompatibility New MCA527 command.Execution right NecessaryDescription The command is intended for

Page 20

Description of the MCA527 Firmware CommandsCommand name CMD_STOP_EXTENSION_PULSERCompatibility New MCA527 command.Execution right NecessaryDescription

Page 21

MCA527MCA Query Commands: Command nameCMD_QUERY_POWERCompatibility Compatible to the MCA166 command.Execution right Not necessaryDescription The comma

Page 22

Description of the MCA527 Firmware CommandsCommand nameCMD_QUERY_POWER (Continuation)Result data arrayByte offset 72 +12V primary current [mA] at stop

Page 23

Description of the MCA527 Firmware CommandsATTENTION! This description is subject to change. The current one refers to MCA527 firmwareversi

Page 24

MCA527Command name CMD_QUERY_SYSTEM_DATACompatibility Compatible to the MCA166 command.Execution right Not necessaryDescription The command reads the

Page 25

Description of the MCA527 Firmware CommandsCommand name CMD_QUERY_SYSTEM_DATA (Continuation)Result data arrayByte offset 124 unused 2 bytesByte offset

Page 26

MCA527Command name CMD_QUERY_STATECompatibility Compatible to the MCA166 command.Execution right Not necessaryDescription The command reads the state.

Page 27

Description of the MCA527 Firmware CommandsCommand name CMD_QUERY_STATE (1st Continuation)Result data arrayByte offset 48 Amplifier coarse gain unsig

Page 28

MCA527Command name CMD_QUERY_STATE (2nd Continuation)Result data arrayByte offset 100 Start time unsigned long See CMD_STARTByte offset 104 TDF unsig

Page 29

Description of the MCA527 Firmware CommandsCommand name CMD_QUERY_STATE527Compatibility New MCA527 command.Execution right Not necessaryDescription Th

Page 30

MCA527Command name CMD_QUERY_STATE527 (1st Continuation)Result data arrayByte offset 58 Power module firmware version unsigned char High nibble: majo

Page 31

Description of the MCA527 Firmware CommandsCommand name CMD_QUERY_STATE527 (2nd Continuation)Byte offset 126 Checksum unsigned shortByte offset 128 MC

Page 32 - CMD_SET_THRESHOLD

MCA527Command name CMD_QUERY_STATE527 (3rd Continuation)RemarksFEATURES_ADJUSTABLE_BASELINE_RESTORER: This flag indicates that the MCA527sup

Page 33

Description of the MCA527 Firmware CommandsCommand name CMD_QUERY_STATE527_EXCompatibility New MCA527 command.Execution right Not necessaryDescription

Page 34

MCA527The Ethernet communication uses the UDP protocol with the destination port 50000. The preamble isprefixed 2 bytes (0xA5, 0x5A)

Page 35 - See CMD_SET_TRIGGER_FILTER

MCA527Command name CMD_QUERY_STATE527_EX (Continuation)Result data arrayByte offset 56 Extension port counter 1 unsigned longByte offset 60 Extension

Page 36 - See CMD_SET_FLAT_TOP_TIME

Description of the MCA527 Firmware CommandsCommand name CMD_QUERY_STATE527_EX2Compatibility New MCA527 command (since firmware version 14.00).Executio

Page 37

MCA527Command name CMD_QUERY_USER_DATACompatibility Compatible to the MCA166 command.Execution right Not necessaryDescription The command reads sixtee

Page 38

Description of the MCA527 Firmware CommandsCommand name CMD_QUERY_SPECTRA_EXCompatibility New MCA527 command.Execution right Conditionally necessary (

Page 39

MCA527Command name CMD_QUERY_SPECTRA_EX (Continuation)Buffer control (index51) The index is only relevant for gating mode 'sort by time'. If

Page 40

Description of the MCA527 Firmware CommandsNameCMD_QUERY_EXTENSION_RS232_RXCompatibility New MCA527 command.Execution right Conditionally necessary (s

Page 41

MCA527Command name CMD_QUERY_VOLTAGE_CURRENTCompatibility Identical to the MCA166 command.Execution right Not necessaryDescription The command reads t

Page 42

Description of the MCA527 Firmware CommandsCommand name CMD_QUERY_ENRICHMENTCompatibility Identical to the MCA166 command.Execution right Not necessar

Page 43

MCA527Name CMD_QUERY_UF6_ROISCompatibility Identical to the MCA166 command.Execution right Not necessaryDescription The command reads begin an

Page 44

Description of the MCA527 Firmware CommandsName CMD_QUERY_UF6_INFOCompatibility Compatible to the MCA166 command.Execution right Not necessaryDescript

Page 45

Description of the MCA527 Firmware CommandsMCA Acquire Commands:Command nameCMD_STARTCompatibility Compatible to the MCA166 command.Execution right Ne

Page 46

MCA527Name CMD_QUERY_COMMON_MEMORYCompatibility New MCA527 command.Execution right Not necessaryDescription The command reads 1440 bytes from the comm

Page 47

Description of the MCA527 Firmware CommandsName CMD_QUERY_OSCI_SCREENCompatibility New MCA527 command.Execution right Necessary if the resolution inde

Page 48

MCA527Name CMD_QUERY_OSCI_TRIGGER_FILTER_RESULTSCompatibility New MCA527 command.Execution right NecessaryDescription The command reads data that are

Page 49 - See CMD_QUERY_STATE527_EX

Description of the MCA527 Firmware CommandsName CMD_QUERY_AHRC_HISTOGRAMCompatibility New MCA527 command (since firmware version 13.08).Execution righ

Page 50

MCA527NameCMD_QUERY_ADJUSTMENT_TABLECompatibility New MCA527 command.Execution right Not necessaryDescription The command returns the ADC values that

Page 51

MCA527Command name CMD_STOPCompatibility Compatible to the MCA166 command.Execution right NecessaryDescription In MCA mode the measurement is stopped

Page 52

Description of the MCA527 Firmware CommandsMCA Setup Commands:Command nameCMD_SET_ADC_RES_DISCRCompatibility Compatible to the MCA166 command.Executio

Page 53

MCA527Command name CMD_SET_ROICompatibility Identical to the MCA166 command.Execution right NecessaryDescription The command sets the begin and end of

Page 54

Description of the MCA527 Firmware CommandsCommand name CMD_SET_TIME_PER_CHANNEL527Compatibility New MCA527 command.Execution right NecessaryDescripti